47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-501.11 - Good Repair and Proper Adjustment: Equipment shall be maintained in good repair.
Corner panel in walk in freezer separating/curving out of place. Repair to be square and secure. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
Cement walls in the kitchen and stock room are not smooth and easily cleanable, but appear to be clean and in good repair. Cement walls do have some cracks. Minor floor tile damage was observed in the dry storage room. Repair flooring. Milk crates being used for bulk storage creating obstacles to floor cleaning. Store on 6 inch dunnage racks to allow for proper cleaning.
6-101.11 - Surface Characteristics: Floors, floor coverings, walls, wall coverings, and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. |
|
56
|
0.50
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 - Intensity: The light intensity shall be at least 10 foot candles in walk-in refrigeration units and dry storage areas.
Very dim lighting in wash area and along back wall. Repair all lighting to be in good repair and provide at least 50 ft candles in work area. |