NamePRUITTHEALTH - TRENT
Address836 RAY LAGGETT WAY
 
City/State/ZIP
NEW BERN NC 28560
Premise Type16 - Institutional Food Service
CountyCraven
Inspection Date 8/13/2025
Final Score @ Grade
91 A
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 2 Hands clean & properly washed Yes No No 2-301.15 Where to Wash (Pf)- Food employees shall clean their hands in a handwashing sink and may not clean their hands in a sink used for ware washing. -Employee went from dirty dishes to clean dishes without a proper handwash step. Employee was using the "dunk" method where he sprayed his hands and dunked it into a bucket of sanitizer. -Sink closest to warewashing was converted to a handwash sink, but was still being used as a dump sink for spraying dishes. *CDI- Instructed employee of proper place to wash hands and also finished conversion of dump sink into handwash sink. Employee washed hands at handwash sink. **2 points
10 1 Handwashing sinks supplied & accessible Yes No No Repeat 6-301.12 Hand Drying Provision (Pf)- Handwashing sinks shall be provided with individual, disposable towels. -At beginning of inspection the only handwash sink was missing paper towels. *CDI- PIC refilled towel dispenser. 5-205.11 (A)(B) Using a Handwashing Sink - Operation and Maintenance (Pf)- Handwashing sinks shall be maintained so that it is accessible at all times and may not be used for purposes other than handwashing. -Sink closest to dish machine was still being used as a dump sink after being converted to a handwash sink. *CDI- Spoke to administrator and PIC about its documented change of use from a dump sink to a handwash sink. Which occurred 6/5/2023 according to documentation. 6-301.14 Handwashing Signage (C)- A sign that notifies food employees to wash their hands shall be provided at all handwashing sinks used by food employees and shall be clearly visible to food employees. -Converted sink needs a handwash sign. **1 point
22 0 Proper cold holding temperatures Yes No No 3-501.16 (A) (2) and (B) Time / Temperature Control for Safety Food, Cold Holding (P)- Temperature Control For Safety Food shall be maintained at 41F or below. -One of the RIC doors was left open over night and the food inside was temping at 62F. -Ambient of RIC was 62F. *CDI- Items in RIC were voluntarily discarded. **0 points (PIC recognized and corrected issue before REHSI discovered cold holding violation)
38 1 Insects & rodents not present; no unauthorized animals No No No 6-501.111 Controlling Pests (C)- Premises shall be maintained free of pests and the presence of pests shall be controlled by routinely inspecting the premises for evidence of pests. -A large accumulation of roaches were found in an electrical box above three-comp sink. **1 point
39 0 Contamination prevented during food preparation, storage & display No No No 3-305.11 Food Storage - Preventing Contamination from the Premises (C)- Food shall be protected from contamination by storing the food at least 6 inches above the floor. -Food stored on the floor in the WIF. *0 points
40 0.50 Personal cleanliness No No No Repeat 2-402.11 Effectiveness - Hair Restraints (C)- Food employees shall wear hair restraints such as a beard net. -Employees cleaning dishes were not wearing a beard guard. *0.5 points
43 1 In-use utensils: properly stored No Yes No Repeat 3-304.12 In-Use Utensils, Between-Use Storage (C) During pauses in dispensing utensils shall be stored in the food with their handles above the top of the food. -Flour scoop stored with handle in the flour, and sugar scoop stored with handle in the sugar. *1 Point
47 0.50 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used No No No 4-501.11 Good Repair and Proper Adjustment - Equipment (C)- Equipment shall be maintained in a state of good repair. -Air curtain for receiving door does not engage. -Handwash sink needs recaulked as it is separating from the wall. -Gasket is torn from RIC, causing the door to be unable to close. Leading to the temperature violation. -Drainage line from steamer is completed rusted and separated from the pipe. 4-101.19 Nonfood-Contact Surfaces (C)- Nonfood-contact surfaces of equipment that are exposed to splash or spillage shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. -Unsealed wooden board is being used to prop up ice machine, it is absorbent and had absorbed plenty of water from leaks or spills. *0.5 points
49 1 Non-food contact surfaces clean Yes Yes No REPEAT 4-602.13 Nonfood Contact Surfaces (C): 4-601.11 (B) and (C) Equipment, Food-Contact Surfaces, Nonfood Contact Surfaces, and Utensils (C):Nonfood contact surfaces shall be cleaned at a frequency necessary to keep them clean and shall be kept free of an accumulation of debris. -Bottom of oven and bottom of Reach-ins need cleaning. -Gaskets for RICs need cleaned as well. -Gaskets for RIF needs cleaned. -Gaskets for WIC and WIF need cleaning. *1 Point
51 1 Plumbing installed; proper backflow devices Yes Yes No Repeat 5-203.14 Backflow Prevention Device, When Required (P)- Plumbing system shall be installed to prevent backflow of liquid at each point of use at the food establishment. -Mop sink does not have a backflow preventer installed with hose attached. *CDI- Hose was disconnected. 5-205.15 (B) System Maintained in Good Repair (C) - Plumbing system shall be maintained in good repair. -Leak at drainage line for steamer (hose is completely disconnected) -Leak underneath ice machine *1 point
55 1 Physical facilities installed, maintained & clean No No No Repeat 6-501.11 Repairing - Premises, Structures, Attachments, and Fixtures - Methods (C): Physical facilities shall be maintained in good repair. -Observed rust on the ceilings and vents, -flaking paint on ceiling of kitchen -wall damage throughout kitchen. 6-501.12 Cleaning, Frequency and Restrictions (C): Floors, Walls and ceilings need additional cleaning. Physical facilities shall remain clean. -General cleaning need on floors and under food equipment -Underneath shelving in WIC, WIF, and dry storage needs cleaning. -Floor behind equipment and under three comp need cleaning. *1 point