Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Craven County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
Name37TH STREET PASTA COMPANY
Address2402 NEUSE BLVD
 
City/State/ZIP
NEW BERN NC 28560
Premise Type1 - Restaurant
CountyCraven
Inspection Date 3/20/2026
Final Score @ Grade
94 A
General CommentsDiscussed strategies to keep products cool in the pizza prep top during peak rush: -Small individual lids for each container. -Ice packs below. -Adjust equipment if possible. -Switch out product more frequently while monitoring temps.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 2 Hands clean & properly washed Yes No No 2-301.14 When to Wash (P) -Food employee handled dirty dishes and returned directly to cookline without a proper handwash. CDI - PIC addressed food employee and redirected him to the handwash sink where he washed hands properly.
22 1.50 Proper cold holding temperatures Yes No No 3-501.16 (A) (2) Time / Temperature Control for Safety Food, Cold Holding (P): TCS foods shall be held at 41 degrees or below for cold holding. -Items in the prep top temping at above 41F [see log] CDI: Establishment recently went through a large lunch rush, products were removed by PIC to WIC or RIF to cool. When internal temperatures were taken later, all products were cooling within the proper parameters [see log].
33 0 Proper cooling methods used; adequate equipment for temperature control Yes No No 3-501.15 Cooling Methods (Pf): Approved cooling methods shall be used. -Lasagna [70F] prepared today was tightly covered with lid which prevented effective cooling. *CDI - Vented lasagna and when tested later, internal temperature [60F] indicated the product was cooling properly after intervention. CDI -l Addressed effective cooling techniques [adding ice wands to product, venting products while cooling]. *No points taken due to intervention took place early and it was one item.
47 0.50 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used No Yes No 4-501.11 Good Repair and Proper Adjustment - Equipment (C) -Equipment shall be kept in good repair. -rusting shelves in the WIC. *Repeat; reduced to half credit [gaskets were in good condition].
49 1 Non-food contact surfaces clean No Yes No 4-602.13 Nonfood Contact Surfaces (C): Nonfood contact surfaces shall be kept clean to sight and touch. -Hood has dust and other debris, food build up on the racks in the WIC and the bottom of RIC, excessive dust build up on the top racks in the WIC. -Dust and food debris present on the NFC of the large mixer resulting form over a 12 hour period. -Flour and dust on shelves used for dry storage in the back of the establishment. *Repeat
55 1 Physical facilities installed, maintained & clean No Yes No <<< 6-501.11 Repairing - Premises, Structures, Attachments, and Fixtures - Methods (C): Physical facilities shall be maintained in good repair. -Cracked tiles throughout the cook line. -Ceiling tiles throughout the establishment with damage and in disrepair. -Unsealed concrete starting to pit out in the prep area of the kitchen. -Unsealed wood at handwash sink seen with water damage; recommended sealing the wood to prevent it from deteriorating. <<< 6-501.12 Cleaning, Frequency and Restrictions (C) Facility shall be cleaned as often as necessary. -General cleaning needed throughout the establishment on walls and around/under prep tops and other equipment. <<< 6-201.11 Floors, Walls and Ceilings - Cleanability (C) Floors and floor coverings shall be designed, constructed, and installed so that they are smooth and easily cleanable. -Uncoated concrete floors that is beginning to crack in back of establishment including the dry storage area, dish pit and WIC. *Repeat