Food in good condition, safe & unadulterated |
Yes |
No
|
No |
3-202.15 Package Integrity (Pf) - Observed one can that were dented by the seams. FOOD packages shall be in good condition and protect the integrity of the contents so that the FOOD is not exposed to ADULTERATION or potential contaminants. -CDI- PIC removed dented cans and written on top a large "X" and placed in designated dented can rack. No points taken as it was the only can dented on the can rack. |
|
16
|
1.50
|
Food-contact surfaces: cleaned & sanitized |
No |
No
|
Yes |
4-501.114 Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration and Hardness (P) - Observed quat sanitizer dispenser only able to dispense 100 ppm in concentration after numerous test with both REHS and PIC's quat test strips. Manual and Mechanical Warewashing Equipment, Chemical Sanitization - Temperature, pH, Concentration, and Hardness- A chemical SANITIZER used in a SANITIZING solution for a manual or mechanical operation at contact times specified under 4-703.11(C) shall meet the criteria specified under 7-204.11 , shall be used in accordance with the EPA-registered label use instructions, and shall be used in accordance with paragraphs 4-501.114 (A-F).
(D) If another solution of a chemical is used, the PERMIT HOLDER shall demonstrate to the REGULATORY AUTHORITY that the solution achieves SANITIZATION and the use of the solution shall be APPROVED.
(E) If a chemical SANITIZER other than chlorine, iodine, or a quaternary ammonium compound is used, it shall be applied in accordance with the EPA-registered label use instructions.
REHS will return within 3 days to verify once the quat sanitizer dispenser is dispensing at least 150-400 ppm as stated from manufacturers label. Until then, PIC shall hand pour and utilize test strips to get proper concentration. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
Yes |
4-501.11 Good Repair and Proper Adjustment - Equipment (C) - Observed quat sanitizer dispenser unable to functioning properly and dispensing only 100 ppm when concentrations are suppose to be at least 150-400 ppm. EQUIPMENT shall be maintained in a state of repair and condition that meets the requirements specified under Parts 4-1 and 4-2. EQUIPMENT components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
REHS will return within 3 days to verify once the quat sanitizer dispenser is functioning correctly. |