| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
10
|
0
|
Handwashing sinks supplied & accessible |
No |
No
|
No |
5-202.12 Handwashing Sinks, Installation - C -- The hot water at the men's restroom handsink measured 91F. A handwashing sink shall be equipped to provide water at a temperature of at least 100F through a mixing valve or combination faucet.
0 pts |
|
15
|
0
|
Food separated & protected |
Yes |
No
|
No |
3-302.11 Packaged and Unpackaged Food-Separation, Packaging, and Segregation - P -- Observed ice cream uncovered in the ice cream freezer. Foods shall be kept covered when in storage to prevent contamination. The foods were properly covered to correct the violation.
0 pts |
|
16
|
0
|
Food-contact surfaces: cleaned & sanitized |
No |
Yes
|
Yes |
4-601.11 (A) Equipment, Food-Contact Surfaces, Nonfood-Contact Surfaces, and Utensils - Pf -- Observed some residue/grease/buildup on two containers, the microwave, and sticker on container in clean storage. Equipment food contact surfaces and utensils shall be clean to sight and touch. These items were sent to the dish area to correct this violation.
No points taken due to improvement. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
Yes
|
No |
4-501.11 Good Repair and Proper Adjustment-Equipment - C -- Observed some rusty shelving in units and dunnage racks through out facility. I also observed damage at bottom walls and inside portions of the walk in cooler door and walk in freezer door. Observed ice coming from the compressor pipe in the walk in freezer. Repair or replace any damaged curtains in walk in units. Equipment shall be maintained in good repair and components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications. REPEAT |
|
49
|
1
|
Non-food contact surfaces clean |
No |
Yes
|
No |
4-601.11 Equipment, Food-Contact Surfaces, Nonfood Contact Surfaces, and Utensils; 4-602.13 Nonfood-Contact Surfaces - C -- Observed heavy build-up of grease, dust, and crumbs on tops, sides, legs, feet, wheels of equipment. Build up on the outsides of microwave on line, bun machine, conveyor of charbroiler, microwaves, outsides/insides of ovens, in the gaskets on units through out and speed racks in walk in cooler. I also observed heavy grease build up on the filters and ansul system above bun/burger station and fryer station. Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris and be cleaned at a frequency necessary to preclude accumulation of soil residues. REPEAT |
|
51
|
1
|
Plumbing installed; proper backflow devices |
Yes |
No
|
No |
5-202.14 Backflow Prevention Device, Design Standard - P -- The hose at the can wash had a pistol grip sprayer attached and the water was turned on, which creates continuous pressure on the hose/faucet. The backflow prevention device currently installed is not approved for continuous pressure (ASSE 1011). Employees can either remove the pistol grip sprayer after every use or a dual check valve that meets ASSE Standard 1024 (or other Standard that allows for continuous pressure) may be installed. The employees were educated and the pistol grip sprayer removed to correct the violation. |
|
53
|
0
|
Toilet facilities: properly constructed, supplied & cleaned |
No |
No
|
No |
6-501.18 Cleaning of Plumbing Fixtures - C -- Toilet needs cleaning in women's bathroom. Plumbing fixtures such as handwashing sinks, toilets, and urinals shall be cleaned as often as necessary to keep them clean.
0 pts |
|
54
|
0
|
Garbage & refuse properly disposed; facilities maintained |
No |
No
|
No |
6-202.110 Outdoor Refuse Areas, Curbed and Graded to Drain - C -- Water was puddling in the dumpster corral. Outdoor refuse areas shall be constructed in accordance with law and shall be curbed and graded to drain to collect and dispose of liquid waste that results from the refuse and from cleaning the area and waste receptacles. The water seemed to be pooling up because of the clogged drain at the receptacle.
0 pts |
|
55
|
1
|
Physical facilities installed, maintained & clean |
No |
Yes
|
No |
6-501.12 Cleaning, Frequency and Restrictions - C -- Clean floors and walls paying special attention underneath equipment legs and behind equipment as well as walk in freezer and walk in cooler flooring. Physical facilities shall be cleaned as often as necessary to keep them clean. REPEAT
6-501.11 Repairing-Premises, Structures, Attachments, and Fixtures-Methods - C -- I also observed some areas of low grout and cracked baseboard tiles throughout. Repair walk in cooler floor where damaged. Physical facilities shall be maintained in good repair. REPEAT |