Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLANDON II, THE
Address8200 RIVERBIRCH DR
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/18/2026
Final Score @ Grade
38
General CommentsSeasonal to annual permitting inspection by request of property. Pool has not been permitted this season. Permit not issued. Repair listed items and call EHS Devon when ready for re inspection 7049981122. SDX COVERS ON WALL VERIFIED NO SUCTION Rope Length: 50ft Night Swimming: No

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. EHS observed chlorine at 0ppm.
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. EHS observed pH at less than 6.8.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. 2 weirs missing. Replace. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Debris outside of skimmer basket and settled at bottom of skimmer units. Clean out.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. All rubber end caps on ladders missing.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Rope detached from ring buoy rope and incorrect length.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Provide no openings in fence and/or gate that allows passage of a four inch diameter sphere. Over 4” opening between fence end of fences at building sides. Cover opening. .2528(a) Gate latches shall be 54" in height. Gate latch by pump room not 54” in height. Raise. .2537(b) All gates and doors shall be self-closing, self-latching. Gate by pump room not self closing self latching. Repair. .2528(a) Ground level windows shall not open greater than 4" on to pool deck or child protected by audible alarm. Windows onto pool deck from club house open all the way. Install limiters. .2528(b) Maintain between 30 to 45 inches between bottom horizontal member and the next horizontal member (pre May 1, 2010). Foothold where fence connects to clubhouse. .2528(a) Solid barriers that do not have openings shall contain no indentations or protrusions (greater than 1/2") except for normal construction tolerance . Foothold where fence connects to clubhouse. Install slanted piece to eliminate foothold.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Incorrect rule wording. Replace sign.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep the flow meter operational. Flow meter not operational. Repair.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored in pump room. Pool built in 1984.