Inspection Date 8/24/2026
Final Score @ Grade
8
General CommentsInspection conducted with CPO Billie Campbell. Construction final passed. Conducted operational inspection. Verified flow at 58 GPM at 2800 RPM after a backwash. Filtration pump Pentair Superflo VST 1.5 HP 342002 (2) Hayward WGX1031BHF2 VGBA-2017 Main drains. (2)skimmers equalizer lines plugged. Pool width - 15ft, Rope length - 22 1/2ft, max depth - 5ft Fencing around shower area not required. Door to hotel is the barrier. Permit issued with the following conditions 1) No night swimming 2) Flow meter must remain operable. 3) Pump required at 36 - 63 GPM for minimum turnover and restriction of the skimmer and main drain piping and the filter. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level above the skimmers. Some floating debris on the pool water’s surface. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.