Violation Item Demerits Violation Description CDIRVRComments
10 0 Handwashing sinks supplied & accessible Yes No No One handwashing sign missing from handsink near prep area. 6-301.14 - Handwashing Signage: sign or poster that notifies food employees to wash their hands shall be provided at all handwashing sinks. CDI: Handwashing sign provided during inspection
22 0 Proper cold holding temperatures Yes No No Coleslaw in cold well on front line was found at 44-45F. Cambro pans were double stacked in cold well causing product to be stored above cold holding level of equipment. 3-501.16 - Potentially Hazardous Food (Time/Temperature Control for Safety Food), Hot and Cold Holding: Maintain TCS foods in cold holding at 41F or less. P CDI: PIC moved product to be cooled down and reduced fill level of cold well.
33 0.50 Proper cooling methods used; adequate equipment for temperature control Yes No No Coleslaw in cold well on front line was found at 44-45F. Cambro pans were double stacked in cold well causing product to be stored above cold holding level of equipment. Unit is designed for direct contact cold holding. Please do not store product above fill line of cold well to allow for maintained cold holding at 41F or less. 4-301.11 - Cooling, Heating, and Holding Capacities: Provide equipment in number and capacity so that cooling, heating, and holding temperatures are achieved. Pf CDI: PIC educated above equipment requirements and product lowered below fill line.
36 0.50 Thermometers provided & accurate No No Yes Facility has dish plate thermometer for high temp dish machine but is not functional due to not having batteries installed. Please install batteries in this unit or replace with another device. 4-302.13 Temperature Measuring Devices, Manual and Mechanical Warewashing. (B) In hot water mechanical WAREWASHING operations, an irreversible registering temperature indicator shall be provided and readily accessible for measuring the UTENSIL surface temperature.Pf VR: Please send verification of battery replacement or device replacement within 10 days.
47 0 Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used No No No Multiple work orders are still in progress from initial school opening: -Hood vent system above steamer is not pulling enough moisture through system and is pooling condensation on convection oven and behind equipment. Please work with install company to repair or increase RPM’s of hood system so that sufficient moisture is directed through system. -Hot water temperatures throughout kitchen are not consistent due to differing mixing valve settings. Hot water in kitchen should be set at 120F or greater. Water temp at spray wand near dish machine is registering at 125F. The 3-compartment sink is registering at 110F, other sinks register between 107-115F. Water was also run for a period of time to determine if recirculation was an issue, the temps remained consistent. *Please address* 4-501.11 - Good Repair and Proper Adjustment: Equipment shall be maintained in good repair.
48 0 Warewashing facilities: installed, maintained & used; test strips No No No Dish machine does not have pressure gauge installed. Please work with installer to provide pressure gauge. 4-203.13 - Pressure Measuring Devices, Mechanical Warewashing Equipment: Pressure measuring devices that display the pressures in the water supply line for the fresh hot water sanitizing rinse shall have increments of 1 pound per square inch or smaller and shall be accurate to Lbs per square inch in the range indicated on the manufacturers data plate.