Inspection Date 8/20/2026
Final Score @ Grade
12
General CommentsConstruction final and pre-permit inspection conducted with Mason Garrett, Hot Springs Pools, Rick Pidgeon, Embrey, and CPO Eric Mack. 911 had difficulty hearing me. Recommend having Kings III check the emergency call box. Rocks and mulch built up above grade to eliminate gaps under the fencing, especially around landscape drain. Maintain fencing with no gaps > 2” under the fence and at least 48” high from the outside approach. Fencing at the top of the ramp where retaining wall meets fencing is approved. Fencing not completed at time of inspection. Left at 12:00 PM, returned at 2:10 PM and verified top of retaining wall now fenced off and additional metal bar added to eliminate gaps > 2” under the fence to the left of the fireplace. Filtration pump - Pentair Intelliflo3 VSF 011075 - (2) Hayward WG1032BHF2 VGBA 2017 Feature pump - Pentair Superflo VST 342002 2.2 THP - Pulls through filtration main drains Pool max depth 4ft 6in - Pool width 35 ft 6 in - Rope length 50 ft Permit issued with the following conditions No Night Swimming Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on log sheet for cyanuric acid or main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, and pool water maintenance activities. - Corrected. Left copy of state log sheet.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder missing an endcap. .2521 Install ladders per manufacturer instructions. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gaps > 2” under the fence in places. .2528(a) Maintain 2" or less under fence and/or gate. - Corrected. Brick wall by back gate and areas of fencing < 48” high. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected. Fence section at back corner < 48” high. Discussed installing a wing on the fencing to block access to the top of the retaining wall. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Corrected
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Bags of dry chemicals on the floor of the chemical storage room. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. - Corrected.