Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGRAHAM HOUSE
Address312 N GRAHAM ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/17/2026
Final Score @ Grade
20
General Comments-PERMIT CONDITION NOT MET- Observed flowmeter reading at gpm of 120. Permit restricts flow from 46-80 gpm. Pentair Intelliflo3 VSF 011076, 3 hp pump. Pool built without main drains. PERMIT CONDITIONS: 1. Flow meter must be operable. Flow required at 46 gpm to 80 gpm to meet turnover and flow restriction of number of returns. 2. Portable vacuum required. Pool built without vacuum line. 3. Sump pump required. No main drains. Max depth 4 ft. Pool Width 23 ft. Rope length 35 ft. Immediate Suspension Issued: Failure to maintain proper chlorine and pH levels.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. Observed chlorine at 0 PPM during inspection. Recommend getting auto-chemical feeder calibrated. No direct chlorination allowed. -Immediate Suspension Issued-
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed pH below 7.0 (kit reads to 7.0) Recommend getting auto-chemical feeder calibrated. -Immediate Suspension Issued-
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. Observed shepherds hook attachment on the ground at the start of the inspection. Skimmer net was attached to the pole. -CDI- CPO reattached body hook attachment properly.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(d) Pump room floor shall be kept dry and free of standing water. Observed Pump room wet with puddles of standing water. Ensure maintained dry and free of standing water.