8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One weir with a section of pool noodle attached, not able to move freely. .2518(k) Provide functional weirs. - Corrected. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder extends > 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope 48 feet long. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pre-2010 fence less than 48" high throughout. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
Pre-2010 fence with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4".
Pre-2010 fence with footholds < 30” between horizontals. .2528(a) Maintain at least 30" between bottom horizontal and next horizontal on fence and/or gate. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Deck not sloped to drain, roughly 1/4 inch of standing water. .2522(f) Deck shall be sloped to drain. - Will need to correct before permit is issued for 2027. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Incorrect dialing instructions. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Some chemicals stored in close cupboards with no ventilation. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. |