Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGREYS HARBOR LAKE NORMAN
Address8701 PINNACLE CROSS DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/27/2026
Final Score @ Grade
28
General CommentsInspection conducted with CPO Ronald Haltom. Follow up from inspection on 5/19. Facility changing from annual to seasonal pool. Residents will only be able to access the grill area and other common areas in the pool enclosure when the pool is permitted during the Summer. Will need to apply for annual pool permit to be able to use these areas year-round. Observed roughly 1/4” of standing water on the pool deck around the 4ft 6in depth marker. Prior to 2027 pool permit being issued, will need to make deck meet .2522 of the NC Pool Rules. Deck shall slope 1/4 - 1/2 inch per foot away from pool to an indirect drain or deck edge. Deck shall be impervious, slip resistant, and without any gaps or offsets > 1/2 inches. Decking will need to be inspected by a pool senior prior to scheduling the 2027 pool permit inspection. Permit issued with the following conditions No Night Swimming No label on pump. Will require impeller verification if motor changed to a different HP. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir with a section of pool noodle attached, not able to move freely. .2518(k) Provide functional weirs. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder extends > 6" into pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. Handrail missing escutcheon plate. .2521 Install handrails per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Throw rope 48 feet long. .2530(a) Provide USCG approved ring buoy with attached 50 foot throw rope. - Corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pre-2010 fence less than 48" high throughout. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. Pre-2010 fence with gaps > 4" through the fence. .2528(a) Provide no openings in fence and/or gate greater than 4"x4". Pre-2010 fence with footholds < 30” between horizontals. .2528(a) Maintain at least 30" between bottom horizontal and next horizontal on fence and/or gate.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck not sloped to drain, roughly 1/4 inch of standing water. .2522(f) Deck shall be sloped to drain. - Will need to correct before permit is issued for 2027.
22 6 Premises: emergency telephone provided No No No Incorrect dialing instructions. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in close cupboards with no ventilation. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.