Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOLSTICE AT EASTLAND YARDS
Address5625 HOLLYFIELD DR
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/14/2026
Final Score @ Grade
22
General CommentsIntent to Suspend issued for the following: .2518 - set pump to meet flow range at 72 gpm to 126 gpm - pump speed shall not have an expiration time. .2537 - repair deck damage on left side of pool near tv area. .2524/.2537 - adjust pool signage to indicate dusk or schedule additional site visit for night swimming approval. Pool is not approved for salt as primary chlorination. For night swimming approval, contact Katie Rudisill at 704-309-5494 or katie.rudisill@mecknc.gov. Percell Henderson present during the inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with clothing and empty water bottles/debris. Ensure emptying to ensure filtration system is working correctly. Corrected during the inspection.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy beckets out of place and rope extremely tangled. Length at less than 45 ft. Untangled and corrected during the inspection. Keep ring buoy and rope accessible at all times in case of emergency.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to deck on left side of pool at bench near tv. Opening/offset >1/2". Repair damage to deck. Intent to Suspend issued. Cracking of deck on right side of pool (sun shelf side) near handicap lift. Monitor. If worsens, repair.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Pool signage indicates night swimming - 10:00 am to 10:00 pm. If seeking night swimming approval, an additional site visit is required or signage shall be changed to indicate 10:00 am to dusk or before dark. Intent to Suspend issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Pump setting speeds do not meet minimum turnover. Pump settings shall not expire at 12:00 am. Pump flow required at 72 gpm to 126 gpm to meet turnover and flow restriction of the filter. Intent to Suspend issued. Set pump to ensure range is met. Autofill turned off at time of inspection. Turned and operable during the inspection.