NameMILLWRIGHT, THE
Address18215 CAPRIO ST
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/8/2026
Final Score @ Grade
24
General CommentsInspection conducted with CPO Tommy Pyles. Hayward Saline C 6.0 salt chlorine generator installed. Not looked at during plan review. Pool not permitted for salt for primary chlorination. Have been having issues with emergency phone functioning properly. Ensure that emergency phone provided remains functional, can transmit the location and phone number to 911, and can be called back in the event of a dropped call. Immediate suspension issued 22) G.S. 130A-2(3) Contact Will Harrison (704) 507-6824 for re-inspection once issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No G.S. 130A-2(3) Cyanuric acid added directly to swimming pool. Chemicals must be added per manufacturer’s instructions. Eliminate direct hazard to public. - Immediate suspension item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook not fully inserted into pole, only held in place by one screw. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. - Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone not able to call 911. When trying to call back to phone message that voicemail has not been set up yet. .2530(f) Emergency phone shall remain operable. - Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Eyeball fitting installed on vacuum line. .2518(f) Vacuum lines shall have protective caps. Pools constructed after May 1, 2010, shall have a self-closing cap designed to be opened with a tool. - Intent to suspend item. Flow meter not installed per manufacturer’s instructions. Return piping for erosion chlorinator and salt chlorine generator bypass chlorinator. .2518(g) A flow meter, reading in gallons per minute and accurate to +/- 10% shall be installed per manufacturer instructions. - Intent to suspend item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Faucet in restroom closest to the pool entrance not functioning. .2526(m) Keep restrooms and fixtures clean and in good repair.