Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLANA AT LAKE NORMAN
Address10414 SAM FURR RD
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/26/2026
Final Score @ Grade
14
General CommentsConducted construction final with Aric Barker, Premier Pools and operational permit inspection with CPO Jeffrey Cillie. Punch list items noted on previous inspection corrected. Notes: 1) Pool is approved for salt as primary chlorination. 2) Barrier for pool is lower barrier by corn hole area and building around pool. 3) Generic signage provided at backside of grill area. Facility provided signage does not meet rule requirement. Generic signage shall remain in place. If making new signs ensure “ADULTS SHOULD NOT SWIM ALONE” and “CHILDREN SHOULD NOT USE THE SWIMMING POOL WITHOUT ADULT SUPERVISION” are provided in at least 1 inch lettering. Provide “WARNING - NO LIFEGUARD ON DUTY” in at least 4 inch lettering. Signs must be visible upon entry to the pool. 4) Facility planning to switch to liquid chemical feeder. Ensure automatic controller shuts off when the pump is off. Filtration Pump Jandy E Pump VSSHP3802A(S), 2.8 THP pump with no main drains. Skimmer equalizers disabled per State requirement. Feature Pump Jandy VS FloPro VSFHP3802AS, 2.8 THP pump with (3) Aquastar 2017 A10RCFRxxx drain covers. Max Depth 4 ft.; Pool Width 29 ft.; Rope Length 44 ft. Pool > 1,600 sq ft. Requires 8 feet of clear walkway around the pool. Permit issued with the following conditions 1) No night swimming 2) Filtration pump flow meter must remain operable and read between 104 GPM and 138 GPM for minimum turnover and flow restriction of the suction pipe sizing. 3) Feature pump must remain at 3000 RPM or less due to pipe size limitation in the pump room. 3) Pool barrier is the building. Units 138, 137, 135, 125, 123, and 121 shall remain accessible during inspections. Doors shall self-close self-latch on to patio enclosures. Paper permit will be on our website, https://eh.mecknc.gov/pools, in 3-5 business days for your records. Will give facility 2 weeks to relocate sensor for autofill and install additional depth markers on pool wall and pool deck. Failure to correct will result in a suspension of the pool permit.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir closest to the pump room does not functioning properly, held down by the sensor for the autofill. .2518(k) Provide functional weirs. - Corrected, sensor removed. Will give facility 2 weeks to relocate the sensor to a suitable location.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 26 feet between 4ft 0inch depth markers by ladder in deep end of the pool. .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Depth markers must be non-slip on deck. - Will give facility 2 weeks to correct.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook held in place by metal clip, easy to remove hook. .2530(a) Provide at least 12 ft. long non-telescoping pole with body hook securely attached. - Corrected. Hook bolted to the pole.