Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameWESTMORELAND
Address9500 ROSALYN GLEN DR
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 7/8/2026
Final Score @ Grade
12
General CommentsInspection conducted with CPO Neill RIEK. Filtration and feature pumps pull through the same main drains. Verified filtration system flow meter reading 290 GPM with VFD at 59.99 Hz after a backwash. Verified feature system flow meter reading 60 gpm at 2400 RPM. Some cracking along expansion joints, depth marker, and no diving marker. One no diving marker cracked. Maintain in good condition.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. .2521(b) Ladders shall be installed rigidly.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back gate not self-latching. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Lounge chairs along both ends of the pool < 8 ft from the pool. Insufficient deck space. .2522(a) Provide 8 ft of clear walking space around the outdoor pool at all times (>1600 sq. ft). - Corrected. Lounge chairs moved from one side of the pool, angled at other side of pool. - Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light burnt out in chemical storage room. .2534(6) Provide sufficient lighting in chemical storage room Chemical storage room not accessible. Chemical tanks block back shelving where bicarb is stored. Keep clearance in chemical storage room so chemicals are accessible. .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.