Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameAVALON CARMEL COMMONS
Address11303 CARMEL COMMONS BV
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/1/2026
Final Score @ Grade
8
General CommentsPool not heated. No Night Swimming. Flow meter must remain operable between 87 gpm to 138 gpm for turnover and flow restriction. At time of inspection flow observed slightly below 87, around 85 gpm. ,Operator adjusted diverter valve and corrected to 90 gpm. Salt not approved as primary chlorination. Discussed sizing of salt cell vs chlorinator and usage, volume and bather load. Minimum chemical standards must be maintained through pump system. 22) Emergency phone is Kings III, did not connect to 911 on first call, dropped call on 2nd attempt. Worked correctly on 3rd and 4th attempt. Monitor emergency phone and ensure it is operable at all times. Inspection with Joe Savino and Josiah Fowler

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Main drain checks missing on records. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator added check and corrected. Discussed logs and what is required.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Two gates not self-closing or latching at time of inspection. .2537(b) All gates shall be self-closing, self-latching. Operator corrected to self-close, self-latch. Continue to monitor and repair when out of compliance.