3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 8.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8. Operator adjusted to 7.4 Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Body hook and ring buoy behind cabana and planters, not easily accessible. .2530(a) Lifesaving equipment should be conspicuously and conveniently located. Operator moved to outer edge of pool and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door onto pool deck not latching at time of inspection.
.2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. Operator adjusted to self-close and latch/lock. Corrected.
*permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and furniture within 6 ft of pool.
.2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Operator moved furniture and corrected. |