Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSEVENTEEN HUNDRED, THE
Address1755 LOMBARDY CR
 
City/State/ZIP
CHARLOTTE NC 28203
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/22/2026
Final Score @ Grade
20
General CommentsNo night swimming. Heater off at time of inspection. Permit restriction: Pressure and vacuum gauges must remain operable. Pump flow must be at least 50 GPM for turnover and cannot exceed 300 GPM for number of returns. Suction hazard at 525 gpm. VFD required at 60 hz Inspection with Mercier Loupesi Discussed possibility of removing fencing and gate at front of pool, so door onto pool deck from lounge area would be barrier, including door across bridge and into another building. If this change is made, all doors would need to meet compliance of self-closing, self-latching or alarmed. Submit general in-field plan review application to Health Dept. If this change is going to be made for approval. Mainline 980-314-1620

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No PH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. Operator adjusted to 7.4 Corrected.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook and ring buoy behind cabana and planters, not easily accessible. .2530(a) Lifesaving equipment should be conspicuously and conveniently located. Operator moved to outer edge of pool and corrected.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door onto pool deck not latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or self-closing and child protected by audible alarm. Operator adjusted to self-close and latch/lock. Corrected. *permit item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chairs and furniture within 6 ft of pool. .2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Operator moved furniture and corrected.