Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameONE WEST END
Address2121 CALDERA ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/1/2026
Final Score @ Grade
12
General CommentsInspection conducted with CPO Jeremy Hines and property manager Allen Mzili. Permit condition that flow meter must remain operable and flow is required to be between 39 GPM for minimum turnover and 62 GPM for flow restriction of the skimmer and main drain piping. - Observed at 61 GPM today. From construction final inspection,verified > 45” between access control junction box and the top of the fence. Observed granular cyanuric acid on pool floor and around returns. G.S. 130A-(2)3 Ensure all chemicals are added to the pool per manufacturer’s instructions and pool is kept closed until chemicals have fully dissolved and thoroughly mixed in the pool. - Pre-permit item. Some items from construction need to be addressed. - Trip hazard at sunshelf. Can be temporarily addressed with a cap prior to permit being issued. - Can give 30 days to permanently address if not able permanently addressed on Friday. - Fan in pump room and chemical storage room tied to light switch in pump room. Fans must be wired to operate continuously, can not be tied to light switch. Will need to run separate switches for fans and lights or plate out the wiring for fans so they run continuously. May need an electrical inspection for the work. - Can give 30 days. - No fresh air intake for pump room door and air intake for chemical storage room door painted shut. Plans call for minimum free area of 100 square inches for pump room door and 1900A Air Louvers for chemical storage room door. - Can give 30 days to address. - Foothold at foot showers by both gates. - Can give 30 days to permanently address. Can install full sized showers, ensure that top of shower base is at least 45” from the top of the fence and no other footholds ‘T’ off of the shower post. Pre-permit inspection did not pass G.S. 130A-(2)3 17) 25) 29) Will need to pay a $100 re-inspection fee by calling our office (980) 314-1620 and paying with a credit card prior to scheduling a re-inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Top of the foot showers 36” from the ground. Less than 45” from top of the shower to the top of the fence. .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). - Can give 30 days to permanently address.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Handrail at sunshelf removed. Temporary cap over anchors sticks up 1 inch. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan tied to light switch in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room. - Can give 30 days. Fan tied to light switch in pump room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room. - Can give 30 days. Some chemicals stored in the pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. - Pre-permit item. Bag of dry chemicals on pump room floor. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. - Pre-permit item.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. - Pre-permit item. No toilet paper in restrooms. .2526(l) Provide toilet paper on toilet paper dispensers in restrooms. - Pre-permit item. Piping and flush controls for urinal loose. .2526(m) Keep restrooms and fixtures clean and in good repair.