Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameHOLLIS 7601
Address7601 HOLLISWOOD CT
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/14/2026
Final Score @ Grade
28
General CommentsSeasonal to annual permitting inspection. Performed inspection with CPO and property manager. Unable to issue permit due to various four and six point items. Pool must remain closed. Call Environmental Health front office to request a re inspection when ready. $100 re inspection fee will be required upon request. PERMIT RESTRICTION - PUMP MUST REMAIN SET AT 3450 RPM TO MEET TURNOVER. NO FLOW RESTRICTION. Const. Date: 2003 Rope Length: 45' Night Swim?: N

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. pH observed at 7.0.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Weir right of pool missing. Replace.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No .2523(b) Provide depth markers spaced not to exceed 25 feet when measured along the perimeter of the pool. Distance between 3ft and 4ft depth markers exceeds 25ft. Add depth marker on deck and wall between. .2523(d) The distance between no diving markers shall be no more than 25 feet perimeter or as the crow flies. .2523(d) No Diving markers shall be written in four inch letters or international 6"x6" no diving in red and black on a white background. NO DIVING lettering on deck faded on right side of pool deck. Repaint.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too short. Operator untied knot and corrected. .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Current pole adjustable. Replace with a non-telescoping, non-adjustable, and non-collapsible at least 12 ft pole.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Two clubhouse doors and back gate not self latching. Repair back gate and either repair clubhouse doors or add audible alarm. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. Latch mechanism protruding 2.5 inches and 37in from ground creating a foothold on both front and back gates. Raise or install anti foothold measures above latch.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(e) Provide a spare basket for pump. Current spare pump basket broken. Replace.