Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTEELE CREEK APARTMENTS NORWOOD
Address13515 MONTOY WY
 
City/State/ZIP
CHARLOTTE NC 28273
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/5/2026
Final Score @ Grade
22
General CommentsConducted annual permit inspection with CPO Doug. Annual permit unable to be issued due to immediate suspension items and intent to suspend items. Correct items and call EHS Devon when ready for re inspection 7049981122. Permit not issued and pool unable to open. Const. Date: 10/10/2023 Rope Length: 48' Night Swim?: NO

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
13 4 Pool maintenance: contrasting band on steps and benches No No No .2521(b) Provide at least 2"x 2" tile for contrasting color band within 1" of adjacent tiles and edge of the stair tread. Missing tiles on edge of stairs. Replace. Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. Current body hook pole telescoping. Replace with a solid at least 12ft pole. Immediate suspension item. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope greater than 50ft. Shorten to approved 48ft. Immediate suspension item.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Posted call back number incorrect. Post with correct number 2395051031. Immediate suspension item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Flow meter not operational. Repair. Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor. Bag of chemicals on floor. Raise off floor.