| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. - Corrected. CPO will start checking main drains. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmer baskets with leaves and debris. .2537b(14) Pool maintenance shall include removal of debris from the water surface. - Corrected.
Missing 1 of 4 weirs. .2518(k) Replace missing weirs. - Corrected. Weirs ordered.
2 of 4 skimmer baskets broken. .2518(k) Replace missing or damaged skimmer basket. - Corrected. New skimmer baskets ordered. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladders missing escutcheon plate. .2521 Install ladders per manufacturer instructions.
Handrails missing escutcheon plate..2521 Install handrails per manufacturer instructions.
Ladder missing endcaps. Wall damaged. Maintain in good condition. .2521 Install ladders per manufacturer instructions. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Throw rope for ring buoy too long. .2530(a) Provide USCG approved ring buoy with attached 45 foot throw rope. - Corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back gate catches on sidewalk. .2528(a) Access gates shall swing away from the pool and be self-latching, self-closing. - Corrected. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Eyeball fitting installed one of the vacuum lines near the main pool entrance. .2518(f) Vacuum lines shall have protective caps. Pools constructed after May 1, 2010, shall have a self-closing cap designed to be opened with a tool. - Corrected. Vacuum cap on order.
Spare pump basket not provided. .2518(e) Provide a spare basket for pump. - Corrected. Spare pump basket on order. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Most piping not labeled. .2518(d) Piping and valves shall be labeled with color codes with a legend or labels. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash line extends into backwash pit. .2513(b) Filter backwash shall be discharged through an air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No soap in the restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. |