Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NamePARKVIEW APARTMENTS
Address350 COMMERCE CENTRE DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/18/2026
Final Score @ Grade
8
General CommentsInspection conducted with CPO Jaxon Goldenberg-Sheetz and Johnny Hoffiz. TDH for pump is (0.5x1.13) + (25.5x2.31) = 59.5 or 111 GPM per pump curve. Main drains only capable of handling 119 GPM. TR-140 filter only capable of handling 106 GPM. Since pool was built, facility replaced the filter and the pump. Recommend either installing a larger filter or a variable speed pump to adjust the flow to between 78 GPM for minimum turnover and 106 GPM for the maximum the filter can handle. Ensure signage is in place directing bathers to location of restroom entrance and doors to restrooms left unlocked when the office is closed. Facility planning to install keyfob entry on door that opens onto the pool deck from the restrooms. Will need an electrical permit for any electrical work done. Key fobs for gates and door need to be on a battery backup system or fail closed in the event of a power outage. Permit issued with the following conditions: No night swimming Pressure and vacuum gauges must remain in place with a TDH of between 63 and 82 ft head loss, or 78 GPM to 106 GPM for minimum turnover and restriction of the filter. TDH less than 53 or 119 GPM exceeds the main drains. Gate valve must remain locked in place. Paper permit will be on our website, https://eh.mecknc.gov/pools in 3-5 business days for your records.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Second step missing non-slip tread. .2521 Install ladders per manufacturer instructions. Ladder > 6” from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms > 110 F. .2526(i) Water in restrooms shall not exceed 110 F.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib on pool deck missing a backflow preventer. .2512(b) Water introduced into the pool, either directly or by the circulation system, shall be supplied through an air gap, anti-siphon vacuum breaker, or backflow preventer.