Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLAKEHOUSE ON WYLIE, THE
Address11027 MOONBUG CT
 
City/State/ZIP
CHARLOTTE NC 28278
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/15/2026
Final Score @ Grade
20
General CommentsConducted inspection with CPO Rasaf. Intent to suspend issued for records and flow meter. Items must be corrected within 30 days or immediate suspension may be issued. Call EHS Devon when items are corrected. 7049981122 NOTES: 1) Flow meter must remain operable. Flow shall be maintained at 117 gpm to 196 gpm to meet turnover and flow restriction of the filters. No flow restriction on feature pump. 2)Pool is not approved for salt as primary chlorination. Const. Date: 1/5/2024 Rope Length: 45' Night Swim?: NO

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Inconsistent records for months. Ensure consistently daily and weekly records. Intent to suspend item.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Ring buoy rope too short and falling apart. Operator replaced with new rope at approved 45’ length. No permit action.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Solid barriers that do not have openings shall contain no indentations or protrusions (greater than 1/2") except for normal construction tolerance . Handles on outside of gates protrude more than 2in and are 38 inches high creating a foothold. Operator removed handles to correct foothold. No permit action.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep the flow meter operational. Flow meter not operational. Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Tools and chemicals blocking equipment access. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals in pump room. Move to designated chemical storage room.