8
|
0
|
Hands clean & properly washed |
Yes |
No
|
No |
2-301.12 Cleaning Procedure (P): Employee obtained and lathered soap without first turning on water and rinsing their hands. FOOD EMPLOYEES shall use the following cleaning procedure in the order stated to clean their hands and exposed portions of their arms, including surrogate prosthetic devices for hands and arms: (1) Rinse under clean, running warm water; (2) Apply an amount of cleaning compound recommended by the cleaning compound manufacturer; (3) Rub together vigorously for at least 10 to 15 seconds; (4) Thoroughly rinse under clean, running warm water; and (5) Immediately follow the cleaning procedure with thorough drying using a method as specified under § 6-301.12.
CDI - REHSI discussed cleaning procedure with the employee and the employee properly washed their hands. |
|
45
|
0
|
Single-use & single-service articles: properly stored & used |
No |
No
|
No |
4-903.11 (A) and (C) Equipment, Utensils, Linens and Single-Service and Single-Use Articles - Storing (C): Single service cups at the drive through have the mouth contact portion of the cups exposed at the top of the dispenser. Store single-use and single-service articles to prevent contamination and at least 6 inches off the floor. |
|
47
|
0.50
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
Yes |
4-202.11 Food-Contact Surfaces - Cleanability (Pf): On both slicers, the plastic plates that hold the food item in place are deeply scored and in need of replacing. Multiuse food-contact surfaces shall be smooth, in good repair, free of sharp angles, and finished to have smooth seams and joints. PIC stated that the plates are to be replaced soon.
VERIFICATION that the plastic plates have been replaced required by FRIDAY 4/17/2025. Contact Carter Bowles for verification (336) 843-5620
4-501.11 Good Repair and Proper Adjustment - Equipment (C): Replace rusted wall shelf above vegetable prep sink, address ice drip in the walk in freezer, replace rusted casters on bread racks, Replace missing hinge cover on make unit, Drive thru drink machine leaking from ice machine on top. Equipment shall be maintained in good repair. |
|
49
|
0
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11 (B) and (C) Equipment, Food-Contact Surfaces, Nonfood Contact Surfaces, and Utensils (C): Additional cleaning needed on the side of the make unit closest to the door entering the kitchen area, under shelving in the walk in cooler, and inside of the upright freezer. Non-food contact surfaces and utensils shall be clean to sight and touch. |
|
51
|
0
|
Plumbing installed; proper backflow devices |
No |
No
|
No |
5-205.15 (B) Maintain a plumbing system in good repair (C): Hand sink near the vegetable prep sink is slow to drain. A plumbing system shall be maintained in good repair. |
|
55
|
0
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-501.11 Repairing - Premises, Structures, Attachments, and Fixtures - Methods (C): Continue replacing missing and damaged baseboard throughout the facility, seal any gaps between baseboard tiles and walls throughout, replace rusted escutcheon plates below hand sink near prep sink, repair any warped corner guards that have separated from underlying FRP throughout, clean and evaluate underneath the stainless steel panel behind the 3 compartment sink, if underlying FRP is damaged then replace, Re-caulk stainless steel panel to the wall so that the junction is smooth and easily cleanable, Resurface the basin of the mop sink so that it is easily cleanable, Repair hole in wall where the monitor is at the make line and reseal the wood. Physical facilities shall be maintained in good repair.
6-501.12 Cleaning, Frequency and Restrictions (C): Floor cleaning needed under and behind equipment and shelving. Minor wall cleaning needed behind dry storage shelving. All physical facilities shall be cleaned as often as necessary to keep them clean |
|
56
|
0
|
Meets ventilation & lighting requirements; designated areas used |
No |
No
|
No |
6-303.11 Intensity - Lighting (C): The walk in cooler measured .99 FC and the fry station measured at 25 FC. The lighting intensity shall be: At least 108 lux (10 foot candles) at a distance of 75 cm (30 inches) above the floor, in walk-in refrigeration units and dry FOOD storage areas and in other areas and rooms during periods of cleaning AND ) At least 540 lux (50 foot candles) at a surface where a FOOD EMPLOYEE is working with FOOD or working with UTENSILS or EQUIPMENT such as knives, slicers, grinders, or saws where EMPLOYEE safety is a factor. |
|