Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMODERA LIBERTY ROW
Address7741 LIBERTY ROW DR
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 4/16/2026
Final Score @ Grade
14
General CommentsItems verified during Inspection for Follow-Up: 1. Some gaps around skimmer lids just at ½”. Gaps have been sealed with caulk to eliminate pinch hazard. Continue to monitor. See comment on deck pavers. 2. Small leak at chlorinator. Ensure floor kept dry with no leaks for operating permit. Lid tightened and no active leak after correction at time of inspection. 3. Facility provided signage does not meet height or wording requirements. New signage has been posted, meeting compliance. Note: In addition to correct signage, new facility signage missing the word “THE” for “Children should not use the swimming pool without adult supervision.” 1 inch lettering in height. Advised keeping correct non-custom made signage for compliance. 4. Pool deck on handicap side of pool with limited spacing. No furniture that impedes on 6 ft. deck requirement. Furniture is not within 6 ft of pool. Maintain furniture at this distance. Pool Width 22 ft.; Rope Length 33 ft.; Max Depth 4 ft. All verified Changed to “A” Open for Business. Will issue permit online and deliver seasonal permit to facility. Permit Restrictions: 1) Flow meter must remain operable. Flow required at 56 gpm to 120 gpm to meet turnover and flow restriction of the number of returns. Flow greater than 170 gpm exceeds the main drains. Suction Hazard. Observed at 70 gpm 2) Salt not approved as primary chlorination. No Night Swimming. Pool not heated Updated CPO to Antonio Bradberry, license number: NC*0218255654 Inspection with Randy Lundquist, Antonio Bradbury and Andres Rivas

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing weekly total alkanity and cyanuric acid. Check for “Safety Equip”, not main drains. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator checked required fields and recorded and updated check to “main drains” with “safety equipment” field. Corrected
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Paver by skimmer loose and able to be pulled out of deck. .2537(2) Decks shall be kept in good repair. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Operator secured with caulk and corrected. Other places of deck have small cracks by corner entry, pavers have cracks between other pavers, but less than 1/2” and may not be completely secured to sub deck. Currently meeting compliance for permit, but advised further securing pavers to prevent issues, trip hazards and disrepair in future.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Small leak at lid of chlorinator at time of inspection..2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. Operator had opened morning of inspection. Lid was tightened and monitored, no more leaking after lid was tightened. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Small amount of water on floor by chlorinator. Operator had opened and added tablets morning of inspection. Lid was secured during inspection, tightened and no more water. Corrected. .2533(d) Pump room floor shall be kept dry and free of standing water.