Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameCOMMONS AT UNIVERSITY SQUARE THE
Address9201 GLENWATER DRIVE
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/11/2025
Final Score @ Grade
16
General CommentsInspection conducted with CPO John Dalton. Outer rope on ring buoy and throw rope starting to fray. Recommend replacing with new US Coast Guard approved ring buoy with attached 50 foot throw rope at least 1/4 inches in diameter. Verified new drain covers. Verified pump at max speed, 108 GPM. Permit issued with the following conditions: No Night Swimming Pump required at max speed. Flow meter must remain operable. Flow required at 118 gpm to meet turnover and flow restriction of the main drain. Flow greater than 119 gpm exceeds the main drains. Suction Hazard.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on pool log sheet for main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Corrected. Main drains added to pool log sheet.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladders extend > 6” into the pool. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Some of the windows from the clubhouse that open onto the pool deck capable of opening > 4”. .2528(a) Ground level windows shall not open greater than 4" on to pool deck. - Corrected.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash. .2513(b) Filter backwash shall be discharged through an air gap.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Shower sign not posted. .2526(a) Post a shower sign visible upon entrance to the pool. - Corrected.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Urinal removed from men’s restroom. .2526(f) At least one sink, one toilet, one urinal is required for men's restroom. No soap in restrooms. .2526(j) Provide soap and soap dispenser, no glass, at each sink. Toilet paper dispensers broken or missing in restrooms. .2526(l) Provide toilet paper and dispensers in restrooms.