2
|
0
|
Certified Food Protection Manager |
No |
No
|
No |
2-102.12 (A) PIC shall demonstrate knowledge by being a certified food protection manager.
PIC is not food safety certified. Permit is within 180 days of issuance.
For more information on becoming a certified food protection manager please visit: www.mecknc.gov/foodsafety |
|
41
|
0.50
|
Wiping cloths: properly used & stored |
No |
No
|
No |
3-304.14(D) Maintain dry wiping cloths free of visible debris and soil. Maintain sanitizer containers for in-use cloths free of visible debris and soil.
Observed wiping cloths stored in soiled water inside sani-buckets. |
|
47
|
0
|
Equipment, food & non-food contact surfaces approved, cleanable, properly designed, constructed & used |
No |
No
|
No |
4-202.11 Multiuse food contact surfaces shall be smooth, free of open seams, cracks, chips, pits, sharp internal angles, crevices and assembled to allow access to clean. -Pf racks
4-501.11 Maintain equipment in good repair.
Observed rusted shelving in the walk-in cooler. Replace. |
|
48
|
0.50
|
Warewashing facilities: installed, maintained & used; test strips |
Yes |
No
|
No |
4-501.19 During manual warewashing, maintain the wash solution at a minimum of 110F or as otherwise allowed by the detergent manufacturer label. -Pf
Observed wash solution in 3 comp sink 90F. CDI sink filled with minimum 110F for ware washing. |
|
49
|
0.50
|
Non-food contact surfaces clean |
No |
No
|
No |
4-601.11(C ) Keep non food contact surfaces of equipment clean to avoid build up of dust, food residue or debris.4-602.13 Non food contact surfaces of equipment shall be cleaned frequently to preclude accumulation of soil residues. Observed excess food debris build-up on and around cooking equipment. |
|
55
|
0.50
|
Physical facilities installed, maintained & clean |
No |
No
|
No |
6-101.11/6-201.11 Floors, walls and ceilings shall be designed, constructed, and installed so they are smooth and easily cleanable. Floors shall be non-absorbent in areas subject to moisture. Observed several ceiling tiles are not washable type tiles. Replace with vinyl coated tiles.
6-501.12 Floors, walls, ceilings including the attachments such as soap, towel dispensers; light fixtures; and heat/ac vent covers shall be clean. Caution should be used to minimize food exposure. Observed residue on walls in warewashing area and prep area.
6-201.13 Provide a wall to floor joint that is sealed and coved when flood cleaning methods are used. Floor must be graded to drain to functioning floor drains.
Observed standing water on floor in warewashing area.
6-501.11 Floors, walls, and ceilings including the attachments such as soap and towel dispensers; light fixtures; and heat/ac vents shall be maintained in good repair. Observed holes in walls. Repair. |