| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
No chlorine, 0 ppm at time of inspection.
.2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator.
*Immediate Suspension item |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 8.0 at time of inspection.
.2535(1) Maintain pH at 7.2 to 7.8.
*Immediate Suspension item |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Observed no records being maintained since 8/20. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers full of debris at time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
*Permit item |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder observed starting to rust. .2521(b) Ladders shall be corrosion-resistant. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Chairs and furniture blocking access to ring buoy and body hook in case of emergency. Keep accessible.
.2530(a) Lifesaving equipment should be conspicuously and conveniently located.
*Immediate Suspension item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chair within 6’ of pool.
.2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Moved chair and corrected. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not operable.
.2530(f) Emergency phone shall remain operable.
.2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system.
*immediate Suspension item |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room door unlocked and open with no staff present at time of inspection. Items in equipment room around piping and pump. Bags of dry chemicals on floor in pump and chemical storage room. Hose bib in pumps room broken, missing backflow prevention device. Manager closed door.
.2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies.
.2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. |