Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameALBUM MATTHEWS
Address9930 IDLEWILD RD
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/17/2026
Final Score @ Grade
40
General CommentsImmediate suspension issued for water quality, emergency phone, and body hook and buoy blocked by furniture. Posed “Pool Closed” signs. Correct items and contact Marie Daley at 704-507-6806 when in compliance to lift suspension. Pool MUST REMAIN CLOSED with signage posted until suspesnion is lifted by Health Dept. “E” Immediate Suspension status. Other permit items to verify at return visit include records and skimmers. Inspection with Terrika Howard

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No chlorine, 0 ppm at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. *Immediate Suspension item
3 6 Water quality: pool water pH No No No PH 8.0 at time of inspection. .2535(1) Maintain pH at 7.2 to 7.8. *Immediate Suspension item
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed no records being maintained since 8/20. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *permit item
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmers full of debris at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. *Permit item
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder observed starting to rust. .2521(b) Ladders shall be corrosion-resistant.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Chairs and furniture blocking access to ring buoy and body hook in case of emergency. Keep accessible. .2530(a) Lifesaving equipment should be conspicuously and conveniently located. *Immediate Suspension item
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Chair within 6’ of pool. .2522(a) Provide 6 ft of clear walking space around the outdoor pool at all times. Moved chair and corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone not operable. .2530(f) Emergency phone shall remain operable. .2530(f) Pool telephone shall be capable of directly dialing 911 or another emergency notification system. *immediate Suspension item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room door unlocked and open with no staff present at time of inspection. Items in equipment room around piping and pump. Bags of dry chemicals on floor in pump and chemical storage room. Hose bib in pumps room broken, missing backflow prevention device. Manager closed door. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.