NameALEXAN LOSO
Address3305 SOUTH BLVD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/7/2025
Final Score @ Grade
10
General CommentsFollow-up inspection. Conducted inspection with CPO Mike Campbell. New CPO has taken over pool maintenance from TCR. Intent to suspend issued for lack of records. Correct with daily and weekly records within 30 days. Text EHS Devon when compliant 7049981122 Permit Restriction: Pool pump flow must be at least 74gpm for turnover, not to exceed 138gpm for skimmer and main drain piping limitation. Note: Pump room clearance 6’10” does not meet minimum required height. Pool will loose points for not meeting clearance for ceiling height. Const. Date: 2/25/2025 Rope Length: 40' No night swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. No records available. Maintain daily and weekly records. Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. One out of five weirs missing. Replace. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(a) Pump room shall be weatherproof with a minimum ceiling height of 7 ft. .2534(1) Chemical storage room shall be weatherproof with a minimum ceiling height of 7 ft. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. Chemicals stored in pump room. Move to designated chemical storage room.