Premises Information

Return to Inspections
NameORO AT BALLANTYNE
Address14020 STREAM WY
 
City/State/ZIP
CHARLOTTE NC 28277
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 4/1/2026
Final Score @ Grade
16
General CommentsPermit Restrictions: 1) Filtration Pump Flow meter must remain operable. Flow required at 64 gpm to 120 gpm to meet turnover and flow restriction of the number of returns. 2) Feature Pump Pump required at 1400 rpm or less or flow meter required with flow no greater than 63 gpm due to suction line flow restriction. 3) Furniture not permitted behind decorative feature columns on pool deck. Note: Pool is not approved for salt as primary chlorination. Both pumps pull through same set of main drains. Inspection with Scott Duncan Pool not heated.No Night Swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Chlorine indicated “7.8”, multiple days, not an accurate reading for chlorine. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Operator noted there was an error in recording and it was 10 ppm. Updated and corrected.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Items in skimmer baskets at time of inspection. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. Operator removed and cleaned. Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck, not operable at time of inspection. .2518(g) Keep flow meter operational. *permit item and permit restriction. Operator repaired and adjusted speed of pump for flow meter reading of 90 gpm. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Bags of chemicals on floor at time of inspection. .2534(4) Provide storage for pool chemicals in waterproof containers or store up off the floor.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No No soap in restroom. .2526(j) Provide soap and soap dispenser, no glass, at each sink.