8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Items in skimmer baskets at time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
Operator removed and cleaned. Corrected. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Buoy rope tangled at time of inspection.
.2530(a) Lifesaving equipment should be conveniently located. Operator untangled and corrected. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Side gate not closing or latching at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching.
*Permit item |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Handicap chair removed from deck, creating holes greater than 1/2” in decking. ADA regulates this chair being kept in compliance. Check with regulating agency on ability to remove from deck. If chair is not in deck, holes must be filled to meet pool rules, no gaps greater than 1/2”
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
*Permit item
Chairs at bar area within 6’ of deck clearance.
.2522(a) Provide 6 ft of clear walking space around the pool at all times. Operator moved and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room unlocked for access to construction workers. .2533(a) The equipment room door shall have a permanent lock and be kept locked when not in use by the pool operator.
Chemicals in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Liquid chemicals over dry chemicals.
.2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up.
Items including ADA handicap chair and trash can within 3’ of equipment.
.2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Glass hand soap dispenser in restroom.
.2526(j) Provide soap and soap dispenser, no glass, at each sink. |