Return to Inspections
NameEVOLVE HUNTERSVILLE APARTMENT HOMES
Address1120 AUTUMN FIELD DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/22/2025
Final Score @ Grade
14
General CommentsInspection conducted with CPOs Bryan Bon and Josh Smalley. Pool > 1,600 sq ft. Need 8 feet of clear walkway around the pool. Address labels on emergency phone sign faded. Recommend providing new permanent emergency phone sign with correct address. Made second visit with Bryan Bon to verify electrical panel. Intent to suspend issued 5) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer baskets with leaves and debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Sunshelf built without handrail. .2521(b) Provide handrail from deck to sunshelf that meets requirements.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Electrical panel at back of restrooms next to fence creating a foothold. .2528(b) Horizontals shall not be located less than 45" in height. - Intent to suspend item. Fence < 48” in places due to buildup of mulch. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier. - Intent to suspend item.