| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine puck in skimmers at time of inspection. .2535(4) Maintain chlorine at least 1.0 ppm through NSF approved chlorinator. Pucks in skimmers are imminent hazard.
*Suspension item
Operator removed pucks, but chlorinator not feeding. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Récords do not indicate chemicals in pool. Ensure records are accurate. Discussed with operator.
.2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
1 of 4 weirs missing.
.2518(k) Replace missing weirs. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521(b) Steps greater than 20 ft in width shall have one handrail every 10 ft. No handrail from deck to sun shelf installed. Pool will lose 2 points on inspections for handrail not being present. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gate not latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
*permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not operable.
.2530(f) Emergency phone shall remain operable.
*Suspension item
.2530(f) Emergency notification systems (monitoring services) must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer the phone number and address for the phone to 911. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorinator with alarm on, not feeding. Pump on timer, turning off on weekends, not meeting turnover, feeding disinfectant or working. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions.
*Permit item
.2518 A pump or pumps shall be provided with capacity to recirculate the swimming pool water four times in 24
hours, and shall be so located as to eliminate the need for priming. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not operational. .2518(g) Keep the flow meter operational.
*permit item |
|