5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed incomplete record keeping for March 2026. Intent to suspend permit issued. Correct within 30 days. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope connected to ring buoy at 37 feet 6 inches. CDI- adjusted to approximately 35 feet. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Install flow meter on return line per manufacturer instructions. Observed flow meter non operational. There is a permit condition for this pool for flow. Intent to suspend permit issued. Correct within 30 days. |