Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameTESSA MATTHEWS
Address3110 DOE RIVER WY
 
City/State/ZIP
MATTHEWS NC 28105
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/31/2026
Final Score @ Grade
14
General CommentsInspection completed with Andrew Giles and Cortez King present. Some debris on pool floor. No permit action taken. Maintain clean. Intent to suspend issued for following items listed below. 1. Inadequate record keeping. Ensure the chlorine, pH, and main drains are verified and recorded daily. Ensure total alkalinity and cyanuric acid are recorded at least once weekly. Observed no main drain checks recorded for March 2026 and minimal record keeping for the month of March 2026. 2. Flow meter non operational. Repair so flow can be measured. This is required per permit conditions. Permit conditions - Pump flow must be at least 93 GPM for turnover and cannot exceed 126 GPM for filter restriction. If clarity issues arise a larger pump will be required to ensure turnover is maintained. Salt not approved for primary chlorination.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Observed incomplete record keeping for March 2026. Intent to suspend permit issued. Correct within 30 days.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope connected to ring buoy at 37 feet 6 inches. CDI- adjusted to approximately 35 feet.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Install flow meter on return line per manufacturer instructions. Observed flow meter non operational. There is a permit condition for this pool for flow. Intent to suspend permit issued. Correct within 30 days.