NameLINK APARTMENTS NODA 36TH II
Address3520 PHILEMON AV
 
City/State/ZIP
CHARLOTTE NC 28206
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 7/21/2025
Final Score @ Grade
8
General CommentsEnsure that the automatic chemical feeding system shuts off automatically if there is no flow in the system, such as from a pump failure. Observed the pool sign to give the pool hours as 8am-8pm. The pool does not have a night swimming approval from the Health Department so it cannot be open after sunset or before sunrise. Ensure the sign does not indicate the pool is open before dawn, or after dusk. “Pool Open Dawn to Dusk” is suggested. PERMIT RESTRICTIONS: 1) FILTRATION PUMP-FLOW METER MUST REMAIN OPERABLE. FLOW SHALL BE KEPT AT 44 GPM TO 98 GPM TO MEET TURNOVER AND FLOW RESTRICTION OF THE FILTER. 2)FEATURE PUMP-EITHER FLOW METER SHALL REMAIN OPERABLE WITH FLOW NOT TO EXCEED 62 GPM DUE TO FLOW RESTRICTION OF SUCTION LINE-OR-PUMP SHALL REMAIN SET AT 1000 RPM OR LESS. 3) DICHLORINATION UNIT REQUIRED ON BACKWASH PER CODE ENFORCEMENT. 4) PORTABLE VACUUM REQUIRED Contact C. Elmore at 704-507-6814 when corrections are made.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed the door leading form the lounge to the pool area to self-close, but not to reliably self-latch. The door must be either fully self-closing and self-latching, or be audibly alarmed to alert whenever the door is opened. I.T.S. Issued. Deadline for correction is 8/20/2025. Failure to correct the item by the deadline may result in the closure of the pool.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meters no feature system not operational. Flow meter must work or feature pump must be set at no more than 1000 RPM. It was at 1500 RPM upon arrival. Added to I.T.S. Deadline is 8/20/2025.