Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLODGE AT MALLARD CREEK
Address7815 CHELSEA JADE LN
 
City/State/ZIP
CHARLOTTE NC 28269
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 5/1/2025
Final Score @ Grade
38
General CommentsInspection conducted with CPO Julian Allen. Julian is the new CPO for the pool. Updated CPO information. Piles of sand under some of the returns. This was noted on past inspections. Ensure filters are in good working order. One of the No Diving markers on the pool deck cracked. Maintain in good condition. Some depth markers on pool walls chipping. One depth marker sticker on pool wall starting to peel. Maintain in good condition. Main gate doesn’t always self-latch. Maintain gates self-closing and self-latching. Permit condition that pump be locked at 3110 RPM and flow meter be working and be at 185 GPM due to pipe sizing restriction. Observed pump set at 3450 RPM, pump not locked, and flow meter not working. - Pre-permit item. Pre-permit inspection did not pass 2) 5) 7) 24) Pump not locked at 3110 RPM. There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling (980) 314-1620 and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed chlorine tab in one of the skimmers, and pile of chlorine tabs on pool deck. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Spotty main drain checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. - Pre-permit item.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Buildup of pollen and debris on pool walls. Blue gritty debris and sand on pool floor. .2537(14) Keep pool surface and pool floor free of debris. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level below the skimmers. .2518(k) Water level shall be maintained to assure skimmers are operable. - Corrected.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Steps loose on one of the ladders. .2521 Install ladders per manufacturer instructions.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .Observed new ring buoy with rope > 60 feet long. 2530(a) Provide USCG approved ring buoy with attached 42 foot throw rope at least 1/4 inch in diameter. - Corrected.
22 6 Premises: emergency telephone provided No No No Kings III phone with incorrect phone number posted. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not functioning. .2518(g) Keep flow meter operational. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No One set of lights burned out in pump room. .2533(b) Provide sufficient lighting in pump room. Fan not working in chemical storage room. .2534(3) Provide continuous forced ventilation or cross ventilation in chemical storage room.