Premises Information

Return to Inspections
NamePERCH, THE
Address718 GESCO ST
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/9/2026
Final Score @ Grade
28
General CommentsPermit remains suspended for gates not self-closing and recordkeeping. Permit Restriction: Flow meter shall remain operable with flow at 82 gpm to 120 gpm to meet turnover and flow restriction of the number of returns - or - keep pump set at 3110RPM. Note: 16inches of 3” pipe is limitation for main drain VGB No pool closed signs posted. Corrected during inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Observed pH below 6.8. .2535(1) Maintain pH at 7.2 to 7.8. **Immediate suspension item**
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Observed pH with 7 only. Maintain records properly with the required range of 7.2 to 7.8 for pH. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. **Immediate suspension item** repeat
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy not accessible, behind chairs and an umbrella. .2530(a) Lifesaving equipment should be conveniently located.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed new gates installed. Lower gate has gaps greater than 1/2" within 18 inches of the crash bar on the latch side and on the hinge side. Upper gate has gaps greater than 1/2" within 18" of the crash bar on the hinge side. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed gates not self-closing. .2537(b) All gates and doors shall be self-closing, self-latching. **Immediate suspension item** repeat item
18 4 Premises: lifeguards present or warning signs posted No No No Observed warning sign, not viable from all entrances to pool maintain signs as described below visible from all parts of the pool deck and entrance. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Observed chemical controller reading 009 for ORP. Calibrate/repair machine as needed to ensure proper function. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. **Intent to suspend item***