5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Log book without weekly cyanuric acid and total alkalinity checks.
.2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly.
*Permit item |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Skimmers full of debris a time of inspection.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
*permit item |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Back gate not latching at time of inspection.
.2537(b) All gates and doors shall be self-closing, self-latching.
*Permit item |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone signage missing city and state for address.
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Operator added and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Lock on chemical storage room door not working. Repair/replace. Door will remain open until repaired.
Chemicals in pump room.