Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTILLWATER APARTMENTS
Address8242 RUNAWAY BAY DRIVE
 
City/State/ZIP
CHARLOTTE NC 28212
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/27/2026
Final Score @ Grade
26
General CommentsNoes indicate 2350 RPM with 74 gpm for turnover. Pump is set at 2355, but flow meter displays 74 gpm. No NIght Swimming. Pool not heated. Inspection with Raul Ortiz

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records missing daily maintenance and chemical changes when out of compliance. 2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Discussed with operator. Lack of severity does not warrant permit action at this time.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No 2 of 3 weirs missing a time of inspection. .2518(k) Replace missing weirs.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder loose at entry. .2521(b) Ladders shall be installed rigidly.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Hook of body hook bent straight. Keep in good repair and bent in case of emergency. Operator corrected form to be body hook. .2530(a) Provide at least 12 ft. long pole with body hook securely attached.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate latch locked open at time of inspection. .2537(b) All gates and doors shall be self-closing, self-latching. Operator adjusted and closed to self-close and self-latch. Corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No No 3’ clearance around equipment. Chemicals in pump room. One bag of chemicals on floor. Original construction. 1985. .2534(4) Provide provisions for dry storage in waterproof containers or above the floor on shelves, pallets or dollies. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Original construction. .2513(b) Filter backwash shall be discharged through an air gap.
31 2 Dressing and sanitary facilities: sewage disposed of in a properly operating sewage system No No No No backflow prevention device on hose bib in pump room. Original construction. .2513(b) Provide backflow preventor on fill line to protect the swimming pool from cross contamination.