Final Score @ Grade
20
General CommentsInspection completed with Bryan Burch, Dan Duncan, David Gonzalez, Josh Carroll, Nicole Meier present. See below for in field plan review notes. 1) Permit Restrictions: Flow meter must remain operable. Flow required at 86 gpm to 104 gpm. OBSERVED FLOW AT 86GPM 2) Main drains must remain disabled due to suction hazard or repaired to meet mfg. specifications. OBSERVED MAIN DRAIN LINE CAPPED OFF IN PUMP ROOM. 3) New Pump Hayward TristarVS 900 W3SP3202VSP 1.85 THP - VERIFIED AND ACCURATE 4) Verify straight run pipe at >10” inlet and >4” outlet. OBSERVED 24 INCHES AND 18 INCHES. 5) Blue white flow meter reading the range listed above after backwash. FLOW AT 86GPM. 6) Main drain line should be capped in the pump room. VERIFIED AND ACCURATE. 7) (1) 2” main drain line; (1) 2” skimmer line and (1) 2” return line. VERIFIED AND ACCURATE. 8) (2) Paramount SDX2 2017 drain covers no suction. Incorrect. OBSERVED 2 AQUASTAR A10RCFR DRAIN COVERS INSTALLED. RESUBMIT NEW PDSC PAPERWORK FOR APPROVAL WITH UPDATED INFORMATION. 9) (1) Pentair TR140C filter. VERIFIED AND ACCURATE. 10) 6 returns, either on the floor or the wall - VERIFIED AND ACCURATE. 11) (3) skimmers plugged per State requirement. VERIFIED AND ACCURATE. CPO is Dan Duncan. CPO # is C-093354

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Observed one damaged overflow grate. Replace or permit may be suspended.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide at least 12 ft. long pole with body hook securely attached. Observed 2 body hooks at pool. One body hook had a pole at length less than 12 feet. CDI- pole and hook removed from property. The other body hook with pool remains on pool deck and is in compliance. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed rope at 55 feet. CDI- adjusted to 50 feet.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed one gate not self-latching. CDI- repaired.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. .2530(c) Provide "Adults should not swim alone." in 1" lettering. Observed signage in less than 1 inch letter. CDI- new sign provided and in compliance.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. Low lighting in pump room.