Inspection Date 3/30/2026
Final Score @ Grade
26
General CommentsPOOL IS NOT APPROVED FOR NIGHT SWIMMING. SIGNS SAY POOL HOURS ARE 9AM-9PM. POOL CANNOT BE SHOWING OPEN HOURS AFTER SUNSET OR BEFORE SURISE WITHOUT AN APPROVAL FOR NIGHT SWIMMING. IF YOU WISH TO HAVE THE POOL INSPECTED FOR NIGHT SWIMMING, CONTACT C. ELMORE AT 704-507-6814. CURRENTLY THE POOL CAN ONLY BE OPEN FOR SWIMMING DAWN TO DUSK. CORRECT THE SIGNS. INTENT TO SUSPEND ISSUED FOR ITEMS THAT NEED CORRECTION. DEADLINE IS 4/29/2026. FAILURE TO CORRECT THE ITEMS BY THIS POINT MAY RESULT IN CLOSURE OF THE POOL. OBSERVED PDSC FORM TO GIVE AQUASTAR 12MF COVERS FOR THE MAIN DRAIN COVERS. OBSERVED AQUASTAR 1216 COVERS ACTUALLY INSTALLED. THE GPM FOR THE 1216 COVERS IN THIS POOL APPEARS TO BE 500 GPM WHICH IS SUFFICIENT TO HANDLE THE PUMP FLOW, BUT CORRECTED PDSC INFORMATION MUST BE SENT TO THE HEALTH DEPARTMENT AND APPROVED. THIS MUST BE DONE BEFORE APRIL 7TH 2O26. FAILURE TO HAVE THIS CORRECTED WILL RESULT IN THE CLOSURE OF THE POOL. MAIN DRAIN COVERS EXPIRE 6/2/2030

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. .2535 (4) Lower and maintain cyanuric acid at or below 100 ppm. Observed no records kept since February 20th 2026. Records must be properly kept going forward. I.T.S. Issued.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Required length for this pool is 50 feet. Observed ring buoy to have 47.5 foot rope when 50 foot rope is required. Rope was corrected to 50ft. -CDI.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed the plastic shields on the gates to be too short to comply with the 18 inch requirement. I.T.S. Issued. Correct all of the gates.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed furniture to be too close to the pool. Items were moved back to the 6 foot mark.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Observed the sign that was present to have letters that are 1/4 inch too short. This sign must be corrected. I.T.S. Issued. All of the letters must be 4 inches tall or taller.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter to be non-functional. Correct the flow meter. Pool does not have a flow restriction.