Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMARLEY APARTMENTS, THE
Address1100 FALLS CREEK LN
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/9/2026
Final Score @ Grade
6
General CommentsConducted inspection with CPO. 5% compliant flow meter in pump room. Property submitting new PDSC for approval. Pump 1: 75gpm Pump 2: 70gpm 2nd CPO- MANUEL MONTANO PEREZ - mmontanoperez@s2res.com Requires 5% flow meter for 2026 on Upper Pools. Permit Restrictions: 1) Both systems required to have operable flow meters. 2) Pump 1 - Fountain and Lower Pool - Pump shall be kept at 54 gpm to 98 gpm to meet turnover and flow restriction of the filter. Flow greater than 119 gpm exceeds the main drains. Suction Hazard. 3) Pump 2 - Upper Pools - Pump does not meet turnover at 83 gpm due to flow restriction of the number of returns. Flow greater than 119 gpm exceeds main drains. Suction Hazard. Pump required at 80 gpm. Note: (2) stepping stone SDX2 drain covers not operable per Caribbean - no suction. 4 drains in lower pool - 4 drains in upper pools. 10 drains total with 2 not operable. SDX2 drain covers in the stepping stones - installed 6/1/2024. Const. Date: 1/1/1985 Rope Length: 27' Night Swim?: No

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(b) Maintain no greater than 4" under fence and/or gate (pre-May 2010). Large gap under part of fence left side of pool. Operator corrected with landscaping .2537(b) All gates and doors shall be self-closing, self-latching. Back pickleball gate not self latching. Operator corrected. No permit action.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. No chemical storage room. Pool exempt due to being built in 1985.