8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Múltiple weirs installed upside down and stuck at time of inspection. Some skimmer baskets observed with debris.
.2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
.2518(k) Weirs should remain operable.
Operator cleaned baskets. 4 out of 5 weirs were fixed. One too large and stuck. Advised proper replacement with correct size. Overall correction does not warrant permit action at this time. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Landscapers have placed mulch in some areas of fencing, shortening height of fence to less than 48”. Pool built ‘96. Gaps greater than 2” under gate side with rocks for drainage loose. .2528(a) Pool fence shall be at least 48" in height measured from outside of barrier.
.2528(a) Maintain 2" or less under gate. Operator filled gap and corrected. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs within 6 foot of pool.
.2522(a) Provide 6 ft of clear walking space around the pool at all times.
.2522(e) Provide at least 5 ft of clear walking space around diving board, handrail, slide, or other permanent structure on a swimming pool deck.
Operator moved and corrected. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
No 3’ clearance in pump room. Chemicals stored in pump room. Ventilation not continuos in pump room. Pool built 1996. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room.
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. |
|
28
|
2
|
Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted |
No |
No
|
No |
Shower off at time of inspection.
.2526(h) Shower(s) shall be provided. Provide toilet paper and hand drying. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
No toilet paper in women’s restroom. Paper towels out in men’s in restroom. .2526(l) Provide toilet paper and dispensers in restrooms. Provide hand drying. |