Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameBLVD 98
Address9825 UNIVERSITY CITY BLVD
 
City/State/ZIP
CHARLOTTE NC 28213
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/14/2026
Final Score @ Grade
8
General CommentsPermit Restriction: Flow meter must remain operable. Flow required at 125 gpm to 138 gpm to meet turnover and flow restriction of the suction piping. The below was verified during time of inspection and was in compliance: 1. New Pump Pentair Intelliflo3 VSF 011076, 3 hp 2. Blue White flow meter reading the above flow range. 3. Main drain, skimmer, and return line all 3” pipe through floor. 4. (2) Aquastar R12MFxxx 2017 drain covers. 5. (1) Hayward HCF363T filter 6. (10) returns either on the floor or the wall. 7. (7) skimmers with EQ lines disabled in skimmer and on wall. NIGHT SWIMMING NOT PERMITTED

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2522(a) Provide 6 ft of clear walking space around the pool at all times. Observed some furniture on pool deck less than 6 feet from pool surface. Corrected during inspection to be in accordance with notated rule.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed flow meter not operable. EHS waited for issue to be corrected during inspection, and the required flow range was verified by EHS