Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSPOKE AT TYVOLA STATION
Address5746 WESTPARK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/13/2026
Final Score @ Grade
24
General CommentsInformation on PDSC form verified during today’s inspection. All critical items corrected during today’s inspection with CPO. Not permitted for night swimming. Permit issued.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. Observed two ring buoy with throw ropes tied, one of which measures under the required throw rope length of 30 ft. CDI - CPO removed ring buoy with throw rope < 30 ft as only 1 is required.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Observed sharp edge on coping and offset > 1/2” in other areas of coping around edge of pool. CDI - CPO repaired all areas.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed incorrect callback number posted at pool phone. CDI - Phone number verified and CPO posted correct pool phone number.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No .2518(g) Keep flow meter operational. Observed inoperable flow meter. .2518(f) Observed vacuum port uncovered (located at 4 ft next to ladder).
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Observed old spa equipment in equipment room, no clearance around piping. Chemicals in equipment room. Pool built ‘84. .2533(d) Pump room floor shall be kept dry and free of standing water. Observed water pooling on floor in the pump room due to water leak from pool fill valve and flow meter.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. Observed no air gap at back wash. Pool built ‘84.