Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSPOKE AT TYVOLA STATION
Address5746 WESTPARK DRIVE
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/20/2025
Final Score @ Grade
30
General CommentsCould not issue permit due to following permit items: PDSC information (plug skimmer equalizers on wall), emergency phone (correct information and callback), pole for body hook at least 12 ft and non-telescoping. Contact main line at 980-314-1620 to pay $100 revisit fee, pool ID 501632. Once revisit fee has been paid and all permit items are in compliance. Contact Marie Daley at 704-507-6806 for additional inspection. Pool must remain closed with signage posted until permitted by the Health department. No Night Swimming Pool not heated

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Récords missing main drain check, weekly total alkalinity and cyanuric acid. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Educated staff on how to check these items. *Permit item
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC has been updated and indicated skimmer equalizer lines have been plugged per state recommendations (on wall and in skimmer). At time of inspection old, expired SDX retro covers still on wall. Plug on wall per state recommendation. Dummy covers are allowed, if plugged underneath and indicated on PDSC form. .2539(b) All suction outlets shall be protected by anti-entrapment cover/grates in compliance with APSP-7. .2539(b) All suction fittings shall be installed in accordance with the manufacturer's instructions. *Permit item
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Body hook with telescoping pole. .2530(a) Provide at least 12 ft. long pole with body hook securely attached. .2530(a) Pole for body hook must be non-telescoping, non-adjustable, and non-collapsible. *Permit item
22 6 Premises: emergency telephone provided No No No Emergency phone address incorrect (should have 5746 Westpark Dr, which is address from Polaris of clubhouse, pool does not have own address). When dialed back and connected, phone rings busy. Callback number not posted at time of visit. .2530(f) Emergency notification systems must provide 24 hr. monitoring, be capable of routing calls to 911, and be able to electronically transfer Automatic Number and Locator Identification for the phone. .2530(f) Emergency phone shall remain operable. .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. *Permit item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Spa equipment in equipment room, no clearance around piping. Chemicals in equipment room. Pool built 84. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at back wash. Pool built 84. .2513(b) Filter backwash shall be discharged through an air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Restrooms have been renovated. Ensure backing on mirrors. .2526(k) Provide shatterproof mirrors.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No floor drains in restrooms. Restrooms remodeled, but original construction did not have drains. .2526(c) Floor drains shall be provided in restrooms.