NameBLU SOUTH TOWNHOMES
Address917 BLU CENTRAL RD
 
City/State/ZIP
PINEVILLE NC 28134
Premise Type50 - Seasonal Swimming Pool
CountyMecklenburg
Inspection Date 5/14/2026
Final Score @ Grade
18
General CommentsNOTES: 1) SIGNAGE SHOULD BE INSTALLED ON DOOR LEADING FROM DOG WASH. NO PETS ON POOL DECK. 2) APPROVED RESTROOM IS LOCATED ON POOL DECK. Pool not approved for night swimming

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Three of nine skimmers were missing weirs. Replace missing weirs.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528(a) Maintain 45" between bottom horizontal and next horizontal on fence and/or gate (post-May 2010). Fence closest to green space had two horizontal bars running parallel across that side of fence with bottom bar measuring 18 inches from ground and the other measuring 16 inches from top of fence creating food holds. Management removed horizontal bars during inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept in good repair. Observed one deck tile on the edge of pool closest to clubhouse in which a large portion of tile was broken off creating a sharp edge. Tile was removed and replaced during inspection.
22 6 Premises: emergency telephone provided No No No .2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Phone number listed on signage at emergency phone was inaccurate. Operator posted correct phone number during inspection.