Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameNEXUS 485 APTS
Address2214 NEXUS DR
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/3/2025
Final Score @ Grade
14
General CommentsInspection conducted with CPO Dionisio Acevedo. Flow meter reading 150 GPM. Minimum turnover for pool is 142 GPM, design flow is 190 GMP. Pump set at 2440 RPM. Recommend adjusting pump to get closer to design flow. Maintenance gate doesn’t always latch. Maintain gate self-latching. Keep locked when not in use. Back gate can only be opened from the outside with a key fob. Fix gate so that push bar works. Inspection did not pass 5) 16) Will need to pay a $100 re-inspection fee prior to receiving re-inspection. Re-inspection scheduled for 12:30 PM on 6/9.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No place on log sheet for total alkalinity. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. Left copy of state log sheet. - Pre-permit item.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed no handrail to pool sunshelf. .2521(b) Provide at least one handrail on steps.
18 4 Premises: lifeguards present or warning signs posted No No No Safety signage missing. .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. - Corrected.