8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs. One out of four weirs missing. Replace. No permit action. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Pool reading at 50gpm. Permit restriction states flow meter must read between 103gpm and 138gpm to maintain turnover and account for pipe size limitations. Operator backwashed and turned up pump RPM to 3450. Flow reading at 80gpm. Repair person coming tomorrow to look at pump and flow meter. Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
Some chemicals stored in pump room. All chemicals must be stored in designated chemical storage room. |