Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameNODA FLATS APARTMENTS
Address2509 N DAVIDSON ST
 
City/State/ZIP
CHARLOTTE NC 28205
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/1/2026
Final Score @ Grade
26
General CommentsInspection completed with Beau Cornwell present. Note- intent to suspend permit issued for items listed below. Correct within 30 days or permit may be suspended. 1. Gates not self-latching with each use. 2. Loose depth and no diving tiles on pool deck.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. Observed the pH at 8.0. CDI- adjusted to 7.8.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No .2518(k) Replace missing weirs. Observed 1 missing weir out of 4 total.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Observed loose depth markers around pool deck. Rescure depth markers to pool deck. Intent to suspend permit issued.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Observed ring buoy beckets in poor repair and broken. CDI- new buoy brought on site, old buoy discarded.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Observed both pool gates not self-latching. Intent to suspend permit issued. .2528(a) Gate latches located at less than 54" shall require the use of key, combination lock or card reader or be located on the inside of the gate at least three inches below the top of the gate with no greater than 1/2" within 18" of latch mechanism. Observed 2 inch gap between fencing and push bar within 18 inches of push bar. CDI- area corrected and 2 inch gap eliminated.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(m) Keep restrooms and fixtures clean and in good repair. Observed sink and urinal in mens restroom not functional. Repair.